Electric fire pump controllers

GPx Series

GPx Series

Full Service Electric Fire Pump Controllers with or without Automatic Power Transfert Switch


>  Model GPA - Across-the-line

Dimensions & Submittal Package

>  Model GPP - Partwinding

Dimensions & Submittal Package

>  Model GPR - Autotransformer

Dimensions & Submittal Package

>  Model GPS - Soft Start Soft Stop

Dimensions & Submittal Package

>  Model GPW - Wye-Delta Closed

Dimensions & Submittal Package

>  Model GPY - Wye-Delta Open

Dimensions & Submittal Package



Starting Methods: 

  • GPS                                                                 
  • GPW
  • GPY

Standard, Listings, Approvals and Certifications
• Built to NFPA 20 (latest edition)
• Underwriters Laboratory (UL)
    • UL218 - Fire pump controllers
    • UL 1008 – Automatic power transfer switches for fire pump controllers
    • CSA C22.2 No. 14 Industrial Control Equipment
• FM Global - Class 1321/1323
• New York City - Accepted for use in the City of New York by the Department of Buildings
• Optional: CE Mark - Various EN, IEC & CEE directives and standards
 
Enclosure Protection Rating
Standard: NEMA 2 Assembly
Optional:

• NEMA 12
• NEMA 3
• NEMA 3R
• NEMA 4
• NEMA 4X-304 sst painted
• NEMA 4X-304 sst brushed finish
• NEMA 4X-316 sst painted
• NEMA 4X-316 sst brushed finish
• IP54                                                            
• IP55
• IP65
• IP66

Accessories
• Bottom entry gland plate
• Lifting Lugs
• Keylock handle

Paint Specifications
• Red RAL3002
• Powder coating
 • Glossy textured finish
 
ViZi Touch Operator Interface
• 4.2” color touch screen (HMI technology)
• Embedded microcomputer with software PLC logic
• Expandable storage
• Multi-language
• Upgradable software
 Standard Features 

• Surge Suppression
• Disconnecting means
  o Single operator for both isolating switch and circuit breaker
    o Door interlocked in the ON position
• Suitable as service entrance equipment
• Emergency start handle
• Locked rotor protector
• Readings
   o Voltage and amperage display
   o Cut-in, cut-out and continuous system pressure
• Visual indications:                                                                             
   o Standard Conditions
   o Alarm Conditions
   o Color coded for criticalness
• Remote Alarms (SPDT-8A-250V.AC)
   o Power available
   o Phase reversal o Motor run
   o Common pump room alarm
   o Common Motor trouble

 
Operation

• Automatic start on pressure drop                                
• Start and stop pushbuttons
• Run test pushbutton
• Remote start / deluge valve start provision
• Timers
   o Minimum run timer
   o Sequential start timer
• Pressure or non-pressure actuated
• Automatic or non-automatic Pressure Sensing
• Pressure transducer and run test solenoid valve assembly for fresh water application externally mounted with protective cover Pressure and Event Recorder
• Pressure readings and event recording with date stamp
• Stored in memory for lifetime of controller
• Data viewable on operator interface display screen
• Downloadable by USB port to external memory device

 
Audible Alarm
• 4” alarm bell - 85 dB at 10ft. (3m)
 

 

Automatic Power Transfer Switch - Model GPU


Standard Features
• Surge suppression
• Disconnecting means
   o Single operator for both isolating switch and circuit breaker
   o Door interlocked in the ON position
• Locked rotor protector
• Visual indications
   o Alternate (emergency) isolating switch in the OFF position
   o Alternate (emergency) voltage phase to phase
   o Transfer switch in normal position
   o Transfer switch in Alternate (emergency) position
• Transfer switch test pushbutton
• Bypass for re-transfer and generator shutdown
• Electrically operated and mechanically held in the normal or alternate position
• Provision for manual operation
• Time Delays
   o Momentary normal power outage override (factory set at 3 sec - field adjustable 1 to 3 sec)
   o Alternate (emergency) power available delay (factory set at 3 sec - field adjustable 1 to 3 sec)
   o Transfer trouble delay (factory set at 20 sec - field adjustable 1 to 60 sec) o Retransfer to normal (factory set at 5 min - field adjustable 1 to 20 min)
   o Generator cooldown (factory set at 5 min - field adjustable 1 to 20 min)
• Voltage sensing
   o Transfer to alternate (normal power dropout) 85% of nominal - field adjustable 0 to 100%
   o Phase reversal transfer to alternate o Retransfer to normal (normal power pickup) 90% of nominal - field adjustable 0 to 100%
• Remote alarm contacts
• Generator start connection
 
 Audible Alarm (AIS open)
• 4” alarm bell - 85 dB at 10ft. (3m)

How to order: 

GPx-V/HP/Ph/Hz+ options
GPA- 208/ 30/ 3/ 60 + options

 

 

GPx SPECIFICATIONS - WITHOUT TRANSFER SWITCH
Word File PDF File
English  Français  Español English  French  Español
 GPA-E GPA-F   GPA-E GPA-F  
 GPP-E GPP-F   GPP-E GPP-F  
 GPR-E GPR-F   GPR-E  GPR-F   
 GPS-E GPS-F   GPS-E GPS-F   
 GPW-E  GPW-F   GPW-E GPW-F  
 GPY-E GPY-F   GPY-E GPY-F  

  

GPx + GPU SPECIFICATIONS - WITH TRANSFER SWITCH
Word File PDF File
English  Français  Español English  Français  Español
GPA + GPU-E  GPA + GPU-F    GPA + GPU-E GPA + GPU-F  
 GPP + GPU-E  GPP + GPU-F   GPP + GPU-E GPP + GPU-F  
 GPR + GPU-E  GPR + GPR-F   GPR + GPU-E GPR + GPU-F   
GPS + GPU-E GPS + GPU-F    GPS + GPU-E GPS + GPU-F  
GPW + GPU-E  GPW + GPU-F    GPW + GPU-E GPW + GPU-F  
GPY + GPU-E GPY + GPU-F   GPY + GPU-E GPW +GPU-F  

 

 

  • Site Map
  • Help
  • Privacy Policy
  • © 2001-2012 Tornatech
Subscribe now to our technical bulletins
Tornatech
Address : 7075, Place Robert-Joncas # 132
Phone : 7075, Place Robert-Joncas # 132
Toll-Free : 1 800 363-8448
Fax : 514 334-5448
Postal code: H4M 2Z2

Printed on : May 18, 2012