Model GPL (ViZiTouch V2)

Limited Service Fire Pump Controllers

Model GPL
Limited Service Electric Fire Pump Controller

  • Designed for use with electric motor driven fire pumps.
  • Manufactured in accordance with the NFPA 20 standard and UL listed
  • ViZiTouch 7 inch Color Touch Screen Operator Interface (HMI technology)

Limitations

  • Across the line starting only
  • Horsepower rating of maximum 30hp
  • Can only be installed where acceptable by the authority having jurisdiction
  • Not accepted in FM insured property


Model GPL+ GLU
Limited Service Electric Fire Pump Controller with Automatic Power Transfer Switch

  • Required if normal utility power is not reliable
  • Housed in a barriered compartment or in a separate enclosure attached to the fire pump controller
  • Listed and Approved for fire pump service
  • Equipped with a transfer switch TEST pushbutton

Certifications

Our products respect all of these norms.

  • NFPA
  • CULUS
  • Seismic Compliant
  • Limitations
    • Across the line starting only
    • Horsepower rating of maximum 30hp
    • Can only be installed where acceptable by the authority having jurisdiction
    • Not accepted in FM insured property
  • Surge Suppression
  • Disconnecting means
    • Single operator for circuit breaker
    • Door interlocked in the ON position
  • Suitable as service entrance equipment
  • Emergency start handle
  • Readings
    • Voltage and amperage display
    • Cut-in, cut-out and continuous system pressure
  • Visual indications:
    • Standard Conditions
    • Alarm Conditions
    • Color coded for criticalness
  • Remote Alarms (SPDT-8A-250V.AC)
    • Power available
    • Phase reversal
    • Motor run
    • Common pump room alarm
    • Common Motor trouble
 StandardOptional
208V. to 240V. (1ph & 3ph) 65,000 A.Sym. NOT AVAILABLE
380V. to 480V. 65,000 A.Sym. 65,000 A. Sym.
 600V. 65,000 A.Sym. 25,000 A. Sym.

 

SPECIFICATIONS
  GPL Specifications GPL + GLU Specifications  

GPL SPE 003 E Rev 0 (Word)

GPL-SPE-003-E Rev 0 (PDF) 

GPL+GLU-SPE-003-E Rev 0 (Word) 

GPL+GLU-SPE-003-E Rev 0 (PDF) 

 

DIMENSIONS AND SUBMITTAL PACKAGES  
 SINGLE PHASE   
WITHOUT TRANSFER SWITCH    WITH TRANSFER SWITCH   
 Dimensions only  Submittal Package   Dimensions only   Submittal Package  

GPL-DI600 E

GPL-SV2-1PH-E 

GPL-DI601 E

GPL+GLU-SV2-1PH-E  

THREE PHASE    

GPL-DI600 E

GPL-SV2-3PH-E 

GPL-DI601 E 

GPL+GLU-SV2-3PH-E 

 

Newsletter

Keep up to date !

Subscribe to learn more about us and our products.