GPx Series – Electric Fire Pump Controllers
- Designed for use with electric motor driven fire pumps.
- Available in a wide variety of full and reduced voltage starting methods.
- Manufactured in accordance with the NFPA 20 standard, UL listed and FM Approved.
- ViZiTouch 7 inch Color Touch Screen Operator Interface (HMI technology)
- Models range from 208 to 600 volt, 5 to 500 horsepower, 50 / 60 Hz
- Designed for use with electric motor driven fire pumps.
- Available in a wide variety of full and reduced voltage starting methods.
- Manufactured in accordance with the NFPA 20 standard, UL listed and FM Approved.
- ViZiTouch 7 inch Color Touch Screen Operator Interface (HMI technology)
- Models range from 208 to 600 volt, 5 to 500 horsepower, 50 / 60 Hz
- Surge suppression
- Disconnecting means
- Single operator for both isolating switch and circuit breaker
- Door interlocked in the ON position
- Suitable as service entrance equipment
- Emergency start handle
- Locked rotor protector
- Readings
- Voltage and amperage display
- Cut-in, cut-out and continuous system pressure
- Visual indications:
- Standard Conditions
- Alarm Conditions
- Color coded for criticalness
- Remote Alarms (SPDT-8A-250V.AC)
- Power available
- Phase reversal
- Motor run
- Common pump room alarm (field re-assignable)
- Common Motor trouble (field re-assignable)
- Free (field programmable)
- Built to NFPA 20 (latest edition)
- Underwriters Laboratory (UL)
- UL218 – Fire pump controllers
- UL 1008 – Automatic power transfer switches for fire pump controllers
- FM Global – Class 1321/1323
- New York City – Accepted for use in the City of New York by the Department of Buildings
- Seismic Certification:
- Components are tested in accordance with ICC-ES AC156, IBC 2015 & CBC 2013.
- CBC compliance is not applicable to OSHPD 1 & 4 buildings
- Optional: CE Mark – Various EN, IEC & CEE directives and standards
ViZiTouch V2 Operator Interface
- 7” color touch screen (HMI technology)
- Embedded microcomputer with software PLC logic
- Multi-language
- Upgradable software
Enclosure Protection Rating
- Standard: NEMA 2 Assembly
- Optional:
- NEMA 12
- NEMA 3
- NEMA 3R
- NEMA 4
- NEMA 4X-304 sst painted
- NEMA 4X-304 sst brushed finish
- NEMA 4X-316 sst painted
- NEMA 4X-316 sst brushed finish
- IP54
- IP55
- IP65
- IP66
Accessories
- Bottom entry gland plate
- Lifting Lugs
- Keylock handle
Paint Specifications
- Red RAL3002
- Powder coating
- Glossy textured finish
- Surge suppression
- Disconnecting means
- Single operator for both isolating switch and circuit breaker
- Door interlocked in the ON position
- Locked rotor protector
- Visual indications
- Alternate (emergency) isolating switch in the OFF position
- Alternate (emergency) voltage phase to phase
- Transfer switch in normal position
- Transfer switch in Alternate (emergency) position
- Transfer switch test pushbutton
- Bypass for re-transfer and generator shutdown
- Electrically operated and mechanically held in the normal or alternate position
- Provision for manual operation
- Time Delays
- Momentary normal power outage override (factory set at 3 sec – field adjustable 1 to 3 sec)
- Alternate (emergency) power available delay (factory set at 3 sec – field adjustable 1 to 3 sec)
- Transfer trouble delay (factory set at 20 sec – field adjustable 1 to 60 sec)
- Retransfer to normal (factory set at 5 min – field adjustable 1 to 20 min)
- Generator cooldown (factory set at 5 min – field adjustable 1 to 20 min)
- Voltage sensing
- Transfer to alternate (normal power dropout) 85% of nominal – field adjustable 0 to 100%
- Phase reversal transfer to alternate o Retransfer to normal (normal power pickup) 90% of nominal – field adjustable 0 to 100%
- Remote alarm contacts
- Emergency power isolating switch in the OFF position
- Transfer switch in normal position
- Transfer switch in emergency position
- Generator start connection
Audible Alarm (AIS open)
- 4” alarm bell – 85 dB at 10ft. (3m)