Manufactured in Canada for all markets
Model GPD – Diesel Additive (Foam) Pump Controller
Additive (Foam) Pump Controllers are typically designed for use in buildings where flammable or combustible liquids are present such as aircraft hangers, petro-chemical and hazardous waste facilities.
Choose one of the following configurations:
- C8 – Additive (Foam) pump controller / non pressure actuated without pressure transducer and run test solenoid valve
- C8A – Additive (Foam) pump controller with pressure transducer and run test solenoid valve
Add any of the following options if required:
- C20 – Dump valve circuitry, 24VDC Max2A (Use same voltage as engine batteries)
- Bx79 – Low foam additive level complete with visual indication and alarm contact (DPDT)
- Bx081 – Provision for proof pressure switch for low additive pressure complete with visual indication and alarm contact. (Proof pressure switch provided by others.)
Additive (Foam) Pump Controllers are typically designed for use in buildings where flammable or combustible liquids are present such as aircraft hangers, petro-chemical and hazardous waste facilities.
Choose one of the following configurations:
- C8 – Additive (Foam) pump controller / non pressure actuated without pressure transducer and run test solenoid valve
- C8A – Additive (Foam) pump controller with pressure transducer and run test solenoid valve
Add any of the following options if required:
- C20 – Dump valve circuitry, 24VDC Max2A (Use same voltage as engine batteries)
- Bx79 – Low foam additive level complete with visual indication and alarm contact (DPDT)
- Bx081 – Provision for proof pressure switch for low additive pressure complete with visual indication and alarm contact. (Proof pressure switch provided by others.)
- Designed to control Diesel Engine driven Fire Pumps
- Built to the latest NFPA 20 Standards, UL Listed and FM Approved
- Manual and Automatic Operation
- Built in Battery Chargers
- Pressure and Event Recorder
AC
- 120V/1ph/50-60hz
- 208V to 240V/1ph/50-60hz
DC
- 12VDC
- 24VDC
Grounding system: Negative
Battery chargers
- Two independent fully automatic
- 10A continuous charge
- 500mA trickle charge
Readings
- Electrical readings
- Battery (x2) voltage and amperage
- Charging mode
- Pressure readings (Cut-in cut-out and continuous system pressure)
- Alarm contacts for remote indication*
- Engine run
- Common controller trouble
- Common engine trouble
- Common pump room alarm (field re-assignable)
- H-O-A in OFF or HAND
- Free (field programmable)Alarm contacts for remote indication*
- Visual and audible alarms*
- AC present
- Main switch in AUTO
- Battery #1 & #2 failure
- Charger #1 & #2 failure
- Low oil pressure
- High engine temperature
- Overspeed
- Engine run
- Fail to start
* For a complete list please see submittal packages
- Built to NFPA 20 (latest edition)
- Underwriters Laboratory (UL)
- UL218 – Fire pump controllers
- FM Global – Class 1321/1323
- New York City – Accepted for use in the City of New York by the Department of Building
- Seismic Certification:
- Components are tested in accordance with ICC-ES AC156, IBC 2015 & CBC 2013.
- CBC compliance is not applicable to OSHPD 1 & 4 buildings
- Optional:CE Mark – Various EN, IEC & CEE directives and standards
ViZiTouch 2.1 Operator Interface
- Embedded microcomputer with software PLC logic
- Expandable storage
- 7” color touch screen (HMI technology)
- Upgradable software
- Multi-language
- Enclosure Protection Rating
- Standard: NEMA 2 Assembly
- Optional:
- NEMA 12
- NEMA 3
- NEMA 3R
- NEMA 4
- NEMA 4X-304 sst painted
- NEMA 4X-304 sst brushed finish
- NEMA 4X-316 sst painted
- NEMA 4X-316 sst brushed finish
- IP54
- IP55
- IP65
- IP66
- Accessories
- Bottom entry gland plate
- Lifting Lugs
- Keylock handle
- Paint Specifications
- Red RAL3002
- Powder coating
- Glossy textured finish