GPx Series – Electric Fire Pump Controllers

Manufactured in Canada for all marketsManufactured in Belgium for the European marketsManufactured in Dubai for the Middle East and Asia markets

GPx Series – Electric Fire Pump Controllers

Electric Fire Pump Controllers

  • Designed for use with electric motor driven fire pumps.
  • Available in a wide variety of full and reduced voltage starting methods.
  • Manufactured in accordance with the NFPA 20 standard, UL listed and FM Approved.
  • ViZiTouch 7 inch Color Touch Screen Operator Interface (HMI technology)
  • Models range from 208 to 600 volt, 5 to 500 horsepower, 50 / 60 Hz

Electric FIre Pump Controllers With Automatic Transfer Switch

  • Required if normal utility power is not reliable
  • Housed in a barriered compartment or in a separate enclosure attached to the fire pump controller
  • Listed and Approved for fire pump service
  • Equipped with a transfer switch TEST pushbutton
Certificate Certificate Certificate

Electric Fire Pump Controllers

  • Designed for use with electric motor driven fire pumps.
  • Available in a wide variety of full and reduced voltage starting methods.
  • Manufactured in accordance with the NFPA 20 standard, UL listed and FM Approved.
  • ViZiTouch 7 inch Color Touch Screen Operator Interface (HMI technology)
  • Models range from 208 to 600 volt, 5 to 500 horsepower, 50 / 60 Hz

Electric FIre Pump Controllers With Automatic Transfer Switch

  • Required if normal utility power is not reliable
  • Housed in a barriered compartment or in a separate enclosure attached to the fire pump controller
  • Listed and Approved for fire pump service
  • Equipped with a transfer switch TEST pushbutton
  • Surge suppression
  • Disconnecting means
    • Single operator for both isolating switch and circuit breaker
    • Door interlocked in the ON position
  • Suitable as service entrance equipment
  • Emergency start handle
  • Locked rotor protector
  • Readings
    • Voltage and amperage display
    • Cut-in, cut-out and continuous system pressure
  • Visual indications:
    • Standard Conditions
    • Alarm Conditions
    • Color coded for criticalness
  • Remote Alarms (SPDT-8A-250V.AC)
    • Power available
    • Phase reversal
    • Motor run
    • Common pump room alarm (field re-assignable)
    • Common Motor trouble (field re-assignable)
    • Free (field programmable)
  • Built to NFPA 20
  • Underwriters Laboratory (UL)
    • UL218 – Fire pump controllers
    • UL 1008 – Automatic power transfer switches for fire pump controllers
  • FM Global – Class 1321/1323
  • New York City – Accepted for use in the City of New York by the Department of Buildings
  • Optional: CE Mark – Various EN, IEC & CEE directives and standards

ViZiTouch 2.1 Operator Interface

  • 7” color touch screen (HMI technology)
  • Embedded microcomputer with software PLC logic
  • Multi-language
  • Upgradable software
  • Standard: NEMA 2 Assembly
  • Optional:
    • NEMA 12
    • NEMA 3
    • NEMA 3R
    • NEMA 4
    • NEMA 4X-304 sst painted
    • NEMA 4X-304 sst brushed finish
    • NEMA 4X-316 sst painted
    • NEMA 4X-316 sst brushed finish
    • IP54
    • IP55
    • IP65
    • IP66
  • Accessories
    • Bottom entry gland plate
    • Lifting Lugs
    • Keylock handle
  • Paint Specifications
    • Red RAL3002
    • Powder coating
    • Glossy textured finish
  • Surge suppression
  • Disconnecting means
    • Single operator for both isolating switch and circuit breaker
    • Door interlocked in the ON position
  • Locked rotor protector
  • Visual indications
    • Alternate (emergency) isolating switch in the OFF position
    • Alternate (emergency) voltage phase to phase
    • Transfer switch in normal position
    • Transfer switch in Alternate (emergency) position
  • Transfer switch test pushbutton
  • Bypass for re-transfer and generator shutdown
  • Electrically operated and mechanically held in the normal or alternate position
  • Provision for manual operation
  • Time Delays
    • Momentary normal power outage override (factory set at 3 sec – field adjustable 1 to 3 sec)
    • Alternate (emergency) power available delay (factory set at 3 sec – field adjustable 1 to 3 sec)
    • Transfer trouble delay (factory set at 20 sec – field adjustable 1 to 60 sec)
    • Retransfer to normal (factory set at 5 min – field adjustable 1 to 20 min)
    • Generator cooldown (factory set at 5 min – field adjustable 1 to 20 min)
  • Voltage sensing
    • Transfer to alternate (normal power dropout) 85% of nominal – field adjustable 0 to 100%
    • Phase reversal transfer to alternate o Retransfer to normal (normal power pickup) 90% of nominal – field adjustable 0 to 100%
  • Remote alarm contacts
    • Emergency power isolating switch in the OFF position
    • Transfer switch in normal position
    • Transfer switch in emergency position
  • Generator start connection

Audible Alarm

  • Alarm buzzer – 85dB at 3 meters